SWITCHING CHARACTERISTIC
|
Switching Time ....................250 nsec max. |
|
POWER HANDLING CAPABILITY
|
Without Performance |
Degradation .....................200 mW cw or pulse |
|
|
POWER SUPPLY REQUIREMENTS
|
+5V .................................±2%, 60 mA max. |
-15V ................................±5%, 50 mA max. |
|
CONTROL CHARACTERISTICS
|
Control Input Impedance ............................
|
TTL, advanced Schottky, one unit load. (A unit load is 0.6 mA sink current and 20 μA source current.) |
Control Logic .............................................
|
Logic "0" (-0.3 to +0.8V) for port ON and logic "1" (+2.0 to +5.0V) for port OFF. |
|
OPTION (G09) ENVIRONMENTAL RATINGS
Operating Temperature Range |
|
Operating Temperature Range |
-54°C to +95°C |
Non-Operating Temperature Range.. |
-65°C to +125°C |
Humidity............................................ |
MIL-STD-202F, Method 103B, Cond. B (96 hrs. at 95%) |
Shock................................................. |
MIL-STD-202F, Method 213B, Cond. B (75G, 6 msec) |
Vibration............................................. |
MIL-STD-202F, Method 204D, Cond. B (.06" double
amplitude or 15G, whichever is less) |
Altitude................................................ |
MIL-STD-202F, Method 105C, Cond. B (50,000 ft.) |
Temp. Cycling...................................... |
MIL-STD-202F, Method 107D, Cond. A, 5 cycles |
|
|
AVAILABLE OPTIONS |
|
Option No. |
Description |
G09 |
Guaranteed to meet Environmental Ratings |
G12 |
RoHS Compliant |
G18
|
REACH Compliant |
|
|
|
|
DIMENTIONS AND WEIGHTS |
|