Switching Time........................................... |
25 nsec max. |
Repetition Time.......................................... |
20 MHz max. |
Power Handling Capability |
Without performance degradation........ |
1W cw or peak |
Survival Power........................................ |
1W average, 75W peak (1µsec max. pulse width) |
Power Supply Requirements......................
|
+5V ±2%, 75 mA
-12 to -15V, 50 mA |
CONTROL CHARACTERISTICS |
Control Input Impedance..........................
|
TTL, advanced Schottky, one unit load. (A unit load is 0.6 mA sink current and 20 µA source current.) |
Control Logic.............................................
|
Logic "0" (–0.3 to +0.8V) for switch ON and Logic "1" (+2.0 to +5.0V) for switch OFF.
|
OPTION (G09) ENVIRONMENTAL RATINGS |
|
Operating Temp. Range...........................
|
–55°C to +110°C
|
Non-Operating Temperature Range........ |
–65°C to +125°C |
Humidity.................................................. |
MIL-STD-202F, Method 103B, Cond. B (96 hrs. at 95%) |
Shock.. ....................................................
|
MIL-STD-202F, Method 213B, Cond. B (75G, 6 msec) |
Vibration...................................................
|
MIL-STD-202F, Method 204D, Cond. B (.06" double amplitude or 15G, whichever is less)
|
Altitude.................................................... |
MIL-STD-202F, Method 105C |
Temp. Cycling.......................................... |
MIL-STD-202F, Method 107D, Cond. A, 5 cycles |
AVAILABLE OPTIONS
Option No |
Description |
3 |
SMA female bias/control connectors |
7 |
Type K male RF connectors |
7A |
J1 Type K male; J2 and J3 type K female |
7B |
J1 Type K female; J2 and J3 type K male |
9(1) |
Inverse control logic; logic “0” for port OFF and logic “1” for port ON |
10 |
One type K male (J1) and one type K female (J2) RF connector |
27 |
Single-port toggle control; logic "0" connects J1 to J2 |
33 |
EMI filter solder-type bias/control terminals |
62 |
±15 volts operation |
64A |
SMB male bias/control connectors |
G09 |
Guaranteed to meet Environmental Ratings |
G12 |
RoHS compliant |
G16 |
RoHS & REACH compliant |
|
|
|